250bar Multistage Centrifugal Water Pump
Product Details
250bar Multistage Centrifugal Water Pump
What are the common faults and treatment methods in the work of high-pressure pumps?
错误3:pu后没有流或流量不足mp is started, the pressure is pulsating, and the pipeline shakes
Reason: 1. The air in the pump chamber is not exhausted. 2. The plunger is not properly sealed. 3. The suction filter is clogged. 4. The pressure relief valve or the pressure relief valve is malfunctioning. 5. The pipette is too long and too long.
Solution: 1. Exhaust 2. Replacement, maintenance 3. Cleaning 4. Inspection and elimination 5. Replacement of increased water volume
Fault two: no pressure or insufficient pressure
Reason: 1. The manual pressure relief valve has poor sealing and the pressure adjustment spring is fatigued. 2. The nozzle hole is worn.
Solution: 1. Repair 2. Replace
Trouble three: running noise, big impact, loud sound
Reason: 1. The crankshaft and the bearing bush are severely worn, the clearance is too large, and the connecting rod screw moves.
2. There is debris in the pump, and the gear is damaged 3. Insufficient liquid
Solution: 1. Replace, tighten 2. Clean, replace 3. Check
Fault 4: abnormal oil temperature rise
Reason: 1. Insufficient or excessive oil, oil pollution, oil quantity mismatch, poor viscosity 2. Large gap in the transmission part, friction of auxiliary parts, long running time
Solution: 1. Control according to regulations 2. Check, replace and adjust
Fault five: pump pressure suddenly rises
Reason: The safety valve is faulty, the pressure relief valve is faulty, and the system is faulty.
Solution: Check whether there is maintenance troubleshooting
Fault six: oil leakage lubrication
Reason: 1. The cylinder wall is pulled 2. The piston ring is damaged
Solution: repair and replacement
Fault seven: the cabinet temperature is too high
Reason: 1. Insufficient or excessive lubricating oil 2. The lubricating oil is too dirty, the bearing bush is damaged or starting
Solution: 1. Refuel or clean the oil tank to change the oil 2. Repair the crankshaft or replace the crankshaft r\n
Fault six: serious leakage of plunger seal
Reason: 1. Worn or damaged seal ring. 2 There are serious scratches and scratches on the surface of the plunger.
Solution: 1. Replace the sealing ring 2. Replace or repair the plunger
Hot Tags: 250bar multistage centrifugal water pump, China, manufacturers, suppliers, factory, customized, price, quotation, in stock,Water pump for dirty water,Submersible pump,Hydraulic Submersible Dredge Pump For Excavator,Horizontal Centrifugal Clear Water Pump,High Pressure Submersible Pump,Water Booster Pump System